Foamsulate 50

Foamsulate 50 is a two component, light density, one to one by volume spray applied polyurethane foam. To produce Foamsulate 50 requires the use of an “A” component (ISO) and a blended “B” component (RESIN), which contains ZERO ozone depleting blowing agents, catalysts, polyols and fire retarding materials. Foamsulate 50 is an insulation system designed for use in residential, commercial and industrial applications. Use in lieu of more traditional forms of insulating materials such as fiberglass, cellulose or other loose fill products.
Typical area’s where spray polyurethane foam is applied are:
EXTERIOR WALLS,INTERIOR WALLS,VENTED ATTICS,UN-VENTED ATTIC ASSEMBLIES, BETWEEN FLOORS,CEILINGS

Category:

Specification

Typical Physical Properties

Property Foamsulate 50 Test
R-VALUE 3.7 @ 1″ ASTM C 518
CORE DENSITY 0.5 LB / Cubic Foot ASTM D 1622
OPEN CELL CONTENT > 97% ASTM D 6226
SOUND TRANSMISSION COEFFECIENT 42 ASTM E 413
WATER VAPOR TRANSMISSION – PERMEANCE 21 Perms at 1” ASTM E 96
AIR LEAKAGE RATE < 0.02 (L/s-m2) ASTM E 283
NOISE REDUCTION COEFFICIENT 0.10 ASTM C 423
TENSILE STRENGTH (PSI) 5.19 ASTM D 1623
DIMENSIONAL STABILITY < 5% ASTM D 2126

BUILDING CODE CERTIFICATIONS / FIRE TEST DATA
EVALUATION SERVICE REPORT ICC ESR 3081
EVALUATION SERVICE REPORT ICC – FBC Supplement Florida Building Code – Building
Florida Building Code – Residential
BUILDING TYPES Approved I, II, III, IV, V-B: Nonstructural Insulation material
FLAME SPREAD ASTM E84 Class I < 20
SMOKE DEVELOPMENT ASTM E84 Class I < 400
ASTM E119 Pass Non Load-Bearing – 1 Hour Rated – Wall Assembly
NFPA 259 Pass: Standard fire test method for evaluation of fire propagation characteristics of exterior non-load bearing wall assemblies containing combustible components.
NFPA 285 Pass: Standard fire test method for evaluation of fire propagation characteristics of exterior non-load bearing wall assemblies containing combustible components.
NFPA 286 Pass: Can be used without a 15-minute thermal barrier when covered with one of the approved intumescent coatings as shown on page 2.
NFPA 286 AC377 APPENDIX X Pass: Complies with the applicable requirements of ICC-ES AC377 Appendix X for use in attics and crawlspaces when covered with one of the approved intumescent coatings as shown on page 2.
UL LISTING FWFX.R38039 Exterior Wall System Components
UL LISTING FWFO.EWS0013 Exterior Wall Systems